ESD Information and Control Plan

Learn how electrostatic charge is generated, how ESD damages electronic components and assemblies, how standards structure an effective control programme, and how to create a risk-based ESD control plan. Build an EPA project, add control-plan lines, complete an audit, generate printable signs, save or load JSON and issue a professional PDF report.

AWARENESS EPA CONTROL VERIFICATION ASSURANCE
8
Knowledge and project sections
0
Control-plan lines
0
Risk assessments
0%
Audit checklist complete
JSON / PDF
Portable project and report

What Electrostatic Discharge Means

Most damaging events are below the threshold a person can feel.
Electrostatic discharge (ESD) is the rapid transfer of electrical charge between objects at different electrical potentials. Charge is commonly produced by contact and separation, movement, induction, flowing materials, peeling film or tape, and the handling of insulating packaging.
Critical misconception: no visible spark and no felt shock does not mean the product was safe. Fine semiconductor structures can be damaged by events that are imperceptible to the operator.

HBM

Human Body Model represents a charged person discharging through a device terminal. Personnel grounding is a major control.

CDM

Charged Device Model represents a charged component or assembly discharging rapidly when it contacts a conductor. Automation and handling materials are important.

CBE / CDE

Charged board and cable discharge events can affect assemblies through connectors, test points and external interfaces.

System ESD

Finished-equipment immunity testing is different from manufacturing ESD control and normally uses separate standards.

How Charge Is Generated

ActivityCharging mechanismTypical control
Walking across flooringFootwear contacts and separates from the floor.Qualified footwear/flooring system, testing or continuous monitoring.
Removing a PCB from a bagBoard and packaging surfaces separate.Low-charging shielding packaging and controlled unpacking inside an EPA.
Peeling tape or protective filmRapid material separation generates high charge.Approved low-charging alternatives, distance and ionisation.
Sliding trays, bins or boardsFriction and repeated contact/separation.Qualified dissipative or conductive carriers and process assessment.
Clothing movementGarment layers rub together.Fastened ESD garments and control of exposed synthetic clothing.
Compressed air or moving particlesAirflow and particles charge surfaces.Qualified ionised-air process; avoid uncontrolled air cleaning.
Automated feedersTape, trays and devices charge during movement.Material qualification, grounding, ionisation and device-charge assessment.

Catastrophic failure

Immediate open circuit, short circuit, loss of function, high current or a failed input/output port.

Latent damage

A weakened device may pass production test yet fail early in service, at temperature or under electrical stress.

Soft upset

Reset, data corruption, false triggering, communication interruption, programming errors or temporary loss of function.

Principal Standards and Guidance

Confirm the current contractual edition and obtain authorised copies.
StandardPrimary purposeKey applicationImportant limitation
IEC 61340-5-1:2024Requirements for establishing, implementing and maintaining an ESD control programme.International manufacturing, handling, inspection, rework, storage and service.Lower-withstand products require additional controls or tighter limits; excludes explosive devices and flammable liquids, gases and powders.
ANSI/ESD S20.20-2021Administrative and technical requirements for an ESD control programme.US and global electronics supply chains.Its baseline scope is not evidence that more sensitive products are protected.
JEDEC JESD625CMinimum ESD handling controls for semiconductor devices.Device manufacturing, test, packaging and supply.More device-focused than a complete enterprise programme.
IEC 61340-5-3:2022ESD protective packaging properties, classifications and performance limits.Production, rework, maintenance, transport and storage.Packaging must be correctly selected, undamaged and closed.
IEC TS/PAS 61340-5-6Methods to assess electrostatic risks in actual processes.Charged personnel, conductors, devices, insulators and fields.Complements rather than replaces programme requirements.
ESD TR53Compliance-verification methods for ESD control items.Periodic verification plans and practical testing.Verification does not replace initial qualification.
ANSI/ESD S541Packaging materials for ESD-sensitive items.US-aligned packaging selection and evaluation.Must be integrated with actual handling and transport risks.
ANSI/ESD S8.1Awareness and protective symbols.Product, EPA, packaging and control identification.Symbols do not replace clear local instructions.
ANSI/ESDA/JEDEC JS-001 / JS-002Component HBM and CDM classification test methods.Characterisation of device withstand.Classification is not a factory-control programme.
IEC 61000-4-2System-level ESD immunity test.Finished products and equipment.Not a substitute for production ESD controls.
ISO 10605Road-vehicle ESD test methods.Automotive electronic modules and vehicle interactions.Sector-specific immunity/testing context.
NASA-STD-8739.6 / NASA guidanceEnhanced workmanship and ESD implementation for applicable NASA hardware.Space and mission hardware when invoked.Only applicable where contractually specified.

Requirement Alignment Matrix

Requirement areaIEC 61340-5-1ANSI/ESD S20.20JESD625CTypical gap to check
Documented programme planRequiredRequiredRequired controlsPlan exists but is generic or does not define product sensitivity.
Responsible coordinatorProgramme responsibilityDefined responsibilityOrganisation responsibilityNo competent owner or authority to stop work.
Product qualificationRequiredRequiredMaterial/control qualificationSupplier certificate accepted without use-case qualification.
Compliance verificationRequiredRequired; TR53 supportsExpectedFrequencies arbitrary; reactions and records missing.
Personnel groundingRequiredRequiredRequiredWrist straps checked but flooring, garments or visitors ignored.
Insulator and isolated-conductor controlExplicitRequiredHandling controlsOrdinary plastics, tapes, tools and metal fixtures remain uncontrolled.
IonisationWhere requiredWhere requiredWhere requiredNo decay/balance testing or poor positioning.
PackagingLinks to IEC 61340-5-3Often S541Device packaging“Antistatic” packaging used where shielding is needed.
TrainingRequiredRequiredRequiredAttendance recorded but competence and effectiveness not evaluated.
System-level immunityOutside scopeOutside scopeOutside scopeIEC 61000-4-2 test incorrectly treated as manufacturing control.
Copyright and use note: this app provides an educational summary and implementation aid. It does not reproduce the standards and does not replace authorised copies, competent technical judgement, customer flow-downs or regulatory requirements.

Personnel

  • Wrist straps
  • Footwear and flooring
  • Continuous monitors
  • Groundable garments
  • Training and authorisation

Workstation

  • Common-point ground
  • Dissipative surface
  • Grounded tools and fixtures
  • EPA boundary control
  • Approved cleaning materials

Insulators

  • Remove or substitute
  • Set safe separation
  • Use ionisation
  • Shield exposed product
  • Assess films, tapes and labels

Packaging

  • Low charging
  • Dissipative
  • Conductive
  • Discharge shielding
  • Closed and undamaged

Control Equipment and Verification

Control itemPurposeTypical verificationCommon failure
Wrist strapGrounds seated personnel through controlled resistance.Before use or continuous monitoring.Poor skin contact, broken lead, wrong connection.
Footwear/flooring systemGrounds standing and mobile personnel.Entry test, system resistance and walking-voltage test.Unqualified combination, contamination or insulating socks.
Work surfaceProvides controlled charge decay and reference potential.Resistance to ground and point-to-point measurement.Disconnected ground, wrong cleaner or worn material.
IonizerNeutralises charge on insulators and isolated objects.Offset/balance and charge-decay time.Dirty emitters, wrong distance, blocked airflow, no alarm response.
Continuous monitorMonitors personnel and sometimes work surfaces.Function/alarm check and scheduled formal verification.Alarm ignored or incorrectly set.
Grounded tools and fixturesPrevents isolated conductors and direct discharges.Continuity and resistance checks.Insulating handles, plastic feet, loose bonding lead.
Trolleys, racks and shelvingControlled movement and storage.Ground path/resistance and wheel cleanliness.Plastic wheels or contact lost across floor.
ESD event detectorSupports investigation of discharge activity.Functional check and correlation with process events.Used as sole proof of control or positioned poorly.

Packaging Types

TypeUse and caution
Static-shielding bagPreferred for movement outside an EPA; must be fully closed and undamaged.
Moisture-barrier shielding bagCombines moisture and ESD protection; sealing, desiccant and humidity indicators may be required.
Dissipative bag or toteUseful in controlled handling; may not provide external discharge shielding.
Conductive tote/binSuitable for controlled movement; assess lid, grounding and short-circuit risk.
Conductive/dissipative foamSupports leaded devices and cushioning; control ageing, contamination and compatibility.
Tape, reel, tray, tube or railAutomated handling carriers; assess charge generation during feeding and separation.

PPE and Clothing

ItemBest-practice use
ESD coat/smockFastened, sleeves covering ordinary clothing, maintained and periodically tested.
Groundable garmentConnected exactly as qualified; may provide a defined garment or person grounding path.
ESD footwear/heel groundersUsed only with a qualified flooring system and tested before entry.
ESD gloves/finger cotsControl contamination and charge while preserving dexterity; qualify with the process.
ESD coverall/headwearOften used in cleanrooms and high-control areas.
Sleeve protectorsLimit exposure from ordinary clothing sleeves near ESDS product.
ESD clothing protects product; it does not replace safety PPE for chemicals, heat, mechanical hazards or electrical shock.

Affected Components and Assemblies

TechnologyTypical susceptibilityPossible effect
CMOS, MOSFET, ASIC, FPGA, processors and memoryThin gate oxides, dense geometry and numerous I/O paths.Gate rupture, leakage, logic failure, timing instability or latent degradation.
RF, microwave, GaAs, GaN and low-noise devicesSmall junctions and low-capacitance structures.Reduced gain, increased noise figure, degraded frequency response.
Laser diodes, LEDs and optoelectronicsSensitive junctions and optical interfaces.Loss of optical output, increased threshold, dead pixels or intermittent operation.
MEMS, sensors and magnetic headsTiny electrical and mechanical structures.Stiction, offset, sensitivity loss or mechanical damage.
Precision analogue, ADC/DAC and instrumentationHigh-impedance inputs and tight parameter limits.Offset shift, leakage, noise, loss of calibration or reduced accuracy.
PCBs, flex circuits, hybrids and modulesConnectors and test points provide discharge paths.Multiple component damage, corrupted programming or latent field failure.
Cables and finished equipment interfacesStored cable charge and external touch points.Port damage, reset, communication loss or system upset.

Physical Failure Mechanisms

Oxide puncture

Permanent conductive path through a thin dielectric, causing leakage or complete failure.

Junction or metal melt

Localised high current creates open circuits, shorts or weakened interconnects.

Passivation damage

Surface protection is ruptured, increasing contamination and moisture susceptibility.

Parameter shift

The part remains functional but no longer meets leakage, gain, timing, noise or optical requirements.

ESD versus Electrical Overstress

CharacteristicESDGeneral EOS
SourceAccumulated electrostatic charge.Power supplies, transients, incorrect connection, sequencing or induced current.
DurationUsually extremely short.May be transient or sustained.
EnergyLimited but concentrated with high peak current.Can be substantially greater.
ControlGrounding, bonding, ionisation, EPA and packaging.Design protection, current limiting, correct test and power control.
Failure analysisRequires evidence; do not label all electrical damage as ESD.Look for thermal damage, wrong voltage, polarity or power-sequence evidence.

ESD Control Project

Create a risk-based programme and EPA control plan.
0% complete

Process Risk Assessment

Dynamic ESD Control Plan

Process stepESD risk/sourceRequired controlMethod / limitVerification & frequencyReactionOwner / recordAction

Printable ESD Signage Templates

Edit the wording below and print this section to PDF.

ESD Programme and EPA Audit

Red

ESD Control Plan Report

Generated from the project, risks, controls and audit.
Complete the project and select Generate Report.